Interface for control devices, calibration commands. More...
#include <yarp/dev/IControlCalibration.h>
Inheritance diagram for yarp::dev::IControlCalibration:Public Member Functions | |
| IControlCalibration () | |
| virtual | ~IControlCalibration () |
| Destructor. | |
| virtual yarp::dev::ReturnValue | calibrateAxisWithParams (int axis, unsigned int type, double p1, double p2, double p3)=0 |
| Start calibration, this method is very often platform specific. | |
| virtual yarp::dev::ReturnValue | setCalibrationParameters (int axis, const CalibrationParameters ¶ms)=0 |
| Start calibration, this method is very often platform specific. | |
| virtual yarp::dev::ReturnValue | calibrationDone (int j)=0 |
| Check if the calibration is terminated, on a particular joint. | |
| virtual yarp::dev::ReturnValue | setCalibrator (ICalibrator *c) |
| Set the calibrator object to be used to calibrate the robot. | |
| virtual yarp::dev::ReturnValue | calibrateRobot () |
| Calibrate robot by using an external calibrator. | |
| virtual yarp::dev::ReturnValue | park (bool wait=true) |
| virtual yarp::dev::ReturnValue | abortCalibration () |
| virtual yarp::dev::ReturnValue | abortPark () |
Interface for control devices, calibration commands.
Definition at line 75 of file IControlCalibration.h.
| IControlCalibration::IControlCalibration | ( | ) |
Definition at line 21 of file ImplementControlCalibration.cpp.
|
inlinevirtual |
Destructor.
Definition at line 85 of file IControlCalibration.h.
|
virtual |
Reimplemented in yarp::dev::xHandControlBoard, ControlBoardRemapper, and ControlBoard_nwc_yarp.
Definition at line 51 of file ImplementControlCalibration.cpp.
|
virtual |
Reimplemented in yarp::dev::xHandControlBoard, ControlBoardRemapper, and ControlBoard_nwc_yarp.
Definition at line 60 of file ImplementControlCalibration.cpp.
|
pure virtual |
Start calibration, this method is very often platform specific.
Implemented in yarp::dev::ImplementControlCalibration, yarp::dev::xHandControlBoard, ControlBoardRemapper, and ControlBoard_nwc_yarp.
|
virtual |
Calibrate robot by using an external calibrator.
The external calibrator must be previously set by calling the setCalibration() method.
Reimplemented in ControlBoard_nwc_yarp.
Definition at line 37 of file ImplementControlCalibration.cpp.
|
pure virtual |
Check if the calibration is terminated, on a particular joint.
Non blocking.
Implemented in yarp::dev::xHandControlBoard, ControlBoardRemapper, ControlBoard_nwc_yarp, and yarp::dev::ImplementControlCalibration.
|
virtual |
Reimplemented in ControlBoard_nwc_yarp.
Definition at line 69 of file ImplementControlCalibration.cpp.
|
pure virtual |
Start calibration, this method is very often platform specific.
Implemented in yarp::dev::ImplementControlCalibration, ControlBoard_nwc_yarp, yarp::dev::xHandControlBoard, and ControlBoardRemapper.
|
virtual |
Set the calibrator object to be used to calibrate the robot.
| c | pointer to the calibrator object |
Definition at line 26 of file ImplementControlCalibration.cpp.